techspeclogo.gif (7925 bytes)

Home · Services · Products · History · Projects · FAQ · Help


B2FS Medium SERIES
BRACKISH WATER TO FRESH WATER SYSTEM

wpe11.jpg (9626 bytes)


CAPACITIES: 10,000 TO 33,000 USGPD
(37.9 TO 125 M³D)


OPERATING FEATURES

  • Produces low TDS water utilizing low pressure spiral wound Reverse Osmosis Process

  • 4" diameter thin film composite membranes available with element rejections from 95% to 98.5%.

  • Instrument board containing all process instruments and gauges.

  • Control panel includes ON/OFF system switch for instant start-up/shutdown of unit.

  • Pre- and post-flushes to minimize water hammer and remove supersaturated solutions.

  • Automatic shutdown on high storage level and automatic start-up on predetermined level or operator initiated actions.

  • Sample valves for ease of data collection and trouble shooting.

  • Grooved type cleaning connections for easy maintenance/cleaning with independent stage by stage cleaning operation.

  • Atmospheric break in product line during cleaning to eliminate cross-connection to process water.

  • Unattended operation possible, requires only daily data collection and scheduled preventative maintenance program.

RESISTANCE TO CORROSION

  • Fiberglass reinforced plastic (FRP) for structural skid members, control panel and membrane support.

  • All pressure pipe, hose and fittings constructed of inert thermoplastics.

GENERAL OPERATING SPECIFICATIONS

  • Inlet Water Salinity: up to 3000 mg/l Total Dissolved Solids (higher salinities, consult Hydropro, Inc.)

  • Inlet Water Pressure: 25-60 psig (2-4 kg/cm2).

  • Inlet Water Temperature: 35º F - 113º F (1º C - 45ºC).

  • Inlet Silt Density Index: Less than 4.

  • Turbidity: Less than 1 NTU.

  • Pretreatment: 5 Micron Filtration, scaling and fouling protection as required for particular application.

  • Nominal Salt Passage: 2 to 5% (varies with temperature, pressure and feed water composition).

  • Transmembrane Pressure: 130-195 psig (8.8-13.2 kg/cm2).

  • Product (Permeate) pressure: up to 15 psig (1 kg/cm2).

  • Electric Characteristics: 230/460V, 3 Phase, 60 Hz standard (other voltages and 50 Hz available).

  • Environment: Ventilated, indoors, ambient temperature less than 122ºF (50ºC) and shielded from direct sunlight.

OPTIONAL ACCESSORY EQUIPMENT

  • MEDIA FILTERS
  • CHEMICAL FEED SYSTEMS
  • pH INDICATOR & pH RECORDER FOR INLET WATER pH
  • AUTOMATIC INLET VALVE
  • RAW WATER BOOSTER PUMPS
  • FRP FORCED DRAFT DEGASIFIER & CATCHMENT TANK.
  • SS MICRON FILTER WITH 5 MICRON POLYPROPYLENE CARTRIDGES
  • TRANSFER PUMPS
  • STORAGE TANKS
  • HYDROPNEUMATIC SYSTEMS WITH CONTROLS
  • HIGH SERVICE PUMPS
  • CLEANING SYSTEM
  • TEST EQUIPMENT
  • SPARE PARTS

STANDARD EQUIPMENT SPECIFICATIONS

  • 8" diameter membrane in FRP membrane shells - each with individual permeate sample valve.

  • Vertical Centrifugal Pump 316SS with TEFC motor standard.

  • FRP control panel of essentially NEMA 4X construction, with alarm silence button, full voltage starter(s), integral disconnect switch, control switches, indicating lights, control logic circuits and elapsed time meter.

  • PVC panel board mounted instruments include rotometers for the 40,000 GPD unit and digital indicators/totalizers on all other membrane units.

  • PVC panel board also includes liquid filled SS pressure gauge for permeate and concentrate, pressure switches and gauges for membrane inlet and pump suction, and conductivity indicator for permeate quality.

UNIT SPECIFICATIONS - ENGLISH

MODEL

CAPACITY
(USGPD)

SIZE (Millimeters)
(L x W x H)

Hp

ARRAY

DRY
WEIGHT (lbs)

# OF
ELEMENTS

*CONVERSION
(%)

B2FS-10 10,000 11 x 2.75 x 5 3 1-1-1 464 7 *75
B2FS-15 15,000 11 x 2.75 x 5 5 1-1-1-1 594 11 75
B2FS-20 20,000 11 x 2.75 x 5 5 2-2 x 1 699 15 75
B2FS-27 27,000 11 x 2.75 x 5 5 2-2-2 x 1 900 21 75
B2FS-33 33,000 11 x 2.75 x 5 5 3-3 x 2 995 24 75

 UNIT SPECIFICATIONS - METRIC

MODEL

CAPACITY
(M
3/D)

SIZE (Millimeters)
(L x W x H)

Hp

ARRAY

DRY
WEIGHT (Kg)

# OF
ELEMENTS

*CONVERSION
(%)

B2FS-10 37.9 3600x900x1640 3 1-1-1 211 7 *75
B2FS-15 56.8 3600x900x1640 5 1-1-1-1 270 11 75
B2FS-20 75.7 3600x900x1640 5 2-2 x 1 318 15 75
B2FS-27 102.2 3600x900x1640 5 2-2-2 x 1 409 21 75
B2FS-33 124.9 3600x900x1640 5 3-3 x 2 452 24 75

* Conversion achieved with recycle of Concentrate
Note: Membrane pressure limited to 200 psig (14 Bar)

Specifications subject to change without prior notification

All contents are ©Copyright 2007 Hydropro, Inc., unless otherwise noted
Please direct comments or questions regarding this web site to webmaster@hydropro.com